Response SL5 Manuale delle Istruzioni Pagina 53

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 64
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 52
53
VOICE DIALLER
If an alarm is triggered and the Voice dialler is
activated then the first enabled phone number in the
dialling sequence will be called and the recorded
alarm message will be played. The recipient should
acknowledge the message by pressing the
button on their telephone keypad to shut down the
call sequence. If an acknowledgment signal is not
received, then the next enabled number in the call
sequence will be called. The dialler will continue
calling each enabled number in turn until either all
numbers in the sequence have been dialled or is
cancelled by an acknowledged signal from a recipient.
If an alarm occurs and the Voice Dialler is enabled…
1. The dialler will only activate after the fixed 30s
dialler delay has expired provided the system
has not been disarmed in that period.
2. Each entered phone number will be called in the
order 1 - 2 - 3 - 4
If a number is not entered it will not be dialled.
3. 10s after the number is dialled the appropriate
alarm message will be replayed followed
immediately by the main message.
The alarm and main messages will be repeated
continuously for 60s. After 60s has elapsed the
current message play cycle will be completed and
then the call will be terminated. This ensures the
message is not cut off part way through.
4. 10s delay before next entered number is dialled.
5. After all entered numbers have been dialled
once. There will be a 30s delay before the next
call sequence is started again from the first
entered number.
If a further zone 1 alarm event occurs after
more than 10 minutes then this event will be
transmitted to the AMS.
Remote Manager Diagram
System
Armed
0m 5m 10m 15m
Zn 1
Alarm
event
Zn 1
Alarm
event
Zn 2
Alarm
event
Zn 1
Alarm
event
Initial Zone 1
event...
Zone 1 alarm
event sent
to AMS
2nd Zone 1
event...
occurs within
10 minutes
of last Zn 1
event...
NO
communication
to AMS
Initial Zone 2
event...
Zone 2 alarm
event sent
to AMS
3rd Zone 1
event...
occurs within
10 minutes
of last Zn 1
event...
AMS
Zone 1 alarm
AMS
Zone 2 alarm
AMS
Zone 1 alarm
Message replay
starts
Message play
time expires
10s
60s Message Play Time
Dialler delay
expires number
called
Message replay
complete
Call ended and
line hung up
30s Dialler
Delay
Alarm
Activated
Vedere la pagina 52